DC Tap: 1.5 kV, 10 A, 30 kHz – 8 GHz (-1 dB)
Features
- 1.5 kV DC tap for 30 kHz to 8 GHz (−1 dB)
- Up to 1.5 kV DC voltage (limited by SMA)
- DC input bias current: max. 2 A DC and max. 10 A pulsed
- Typ. 0.4 Ω DC resistance (port 3 to port 1,2)
- SMA 50 Ω thru
- BNC DC
- Size 130.6 mm x 77.6 mm x 31 mm
- Lab safety requirement: interlock operation above an operation voltage of 40 V needed to avoid life-endangerment risks
Download: Product Datasheet DCT-101500B